Product No: 105584
4 Unit High mainframe for one NW-WFx-xxFS (first stroke)
and one NW-WFx-xx-SS (subsequent strokes) module
with connections to MIG-OS-MB.
Controlled by the MIG-OS-MB generator.
NW-WF2-FS
Product No: 103557
DO-160 / ED-14 WF2: 0.1/6.4 µs extends the MIG-OS-MB to level 5
for single stroke or first stroke testing. Requires MIG-OS-MB-EXT.
NW-WF3-10M-FS
Product No: 103553
DO-160 / ED-14 WF3: 10MHz extends the MIG-OS-MB for single stroke
and first stroke testing. No burst possible. Requires MIG-OS-MB-EXT.
NW-WF3-1M-FS
Product No: 103551
DO-160 / ED-14 WF3: 1MHz extends the MIG-OS-MB to level 5
single stroke and first stroke testing. No burst possible.
Requires MIG-OS-MB-EXT.
NW-WF3-1M-SS
Product No: 103552
DO-160 / ED-14 WF3: 1MHz extends the MIG-OS-MB to level 5
subsequent stroke testing. No burst possible. MS definition 1A
100%, 13D/2 50% within 1.5 seconds randomly distributed
50ms up to 110ms). Requires NW-WF3-1M-FS and MIG-OS-MB-EXT.
NW-WF3-1M5-FS
Product No: 103649
WF3: 1.5MHz extends the MIG-OS-MB for
single stroke and first stroke testing. No burst possible.
Requires MIG-OS-MB-EXT and CN-MIG-BT.
Only for Level 3 testing 600V+/-20%/Imax=120A.
NW-WF3-4M3-FS
Product No: 104013
WF3: 4.3MHz extends the MIG-OS-MB for
single stroke and first stroke testing. No burst possible.
Requires MIG-OS-MB-EXT and CN-MIG-BT.
Only for Level 3 testing 600V+/-20%/Imax=90A.
NW-WF3-5M-MB
Product No: 103683
WF3: 5MHz extends the MIG-OS-MB to include fixed frequency
testing for Multiple Burst. Requires MIG-OS-MB-EXT.
NW-WF6H-MB
Product No: 103555
DO-160 / ED-14 WF6H, 0.224/4µs Impulse.14 pulses Multiple Burst only.
The module is controlled by the MIG-OS-MB generator.
Requires MIG-OS-MB-EXT.
MIG-OS-MB-EXT 230V
Product No: 103550
4 Unit High mainframe for one NW-WFx-xxFS (first stroke)
and one NW-WFx-xx-SS (subsequent strokes) module
with connections to MIG-OS-MB.
Controlled by the MIG-OS-MB generator.
NW-WF2-SS
Product No: 103556
DO-160 / ED-14 WF2: 0.1/6.4 µs extends the MIG-OS-MB to level 5
for subsequent stroke testing. MS definition 1A 100%, 23D/2 50%
within 2 seconds randomly distributed 50ms up to 110ms.
Requires NW-WF2-FS and MIG-OS-MB-EXT.
NW-WF3-10M-SS
Product No: 103554
DO-160 / ED-14 WF3: 10MHz extends the MIG-OS-MB for subsequent
stroke testing. No burst possible. MS definition 1A 100%, 13D/2 50%
within 1.5 seconds randomly distributed 50ms up to 110ms).
Requires NW-WF3-10M-FS and MIG-OS-MB-EXT.
NW-WF3-1M-FS-A350
Product No: 105066
DO-160 / ED-14 WF3: 1MHz extends the MIG-OS-MB to
ABD0100.1.2_G lightning test requirement. Range at BT3 coupler
output V/I 50/2A up to1500V/60A, Source impedance V/I= 25 Ohm
for SS and MS first Stroke testing. Needs MIG-OS-MB-EXT.
NW-WF3-1M-SS-A350
Product No: 105067
DO-160 / ED-14 WF3: 1MHz extends the MIG-OS-MB to
ABD0100.1.2_G lightning test requirement. Range at BT3 coupler
output V/I 25/1A up to750V/30A, Source impedance V/I= 25 Ohm
For MS subsequent and MB testing. Requires NW-WF3-1M-FS-A350
NW-WF3-3M-FS
Product No: 103650
WF3: 3MHz extends the MIG-OS-MB for
single stroke and first stroke testing. No burst possible.
Requires MIG-OS-MB-EXT and CN-MIG-BT.
Only for Level 3 testing 600V+/-20%/Imax=90A.
NW-WF3-5M-FS
Product No: 103682
WF3: 5MHz extends the MIG-OS-MB for single stroke and
first stroke testing. No burst possible.
Requires MIG-OS-MB-EXT.
NW-WF3-5M-SS
Product No: 103684
WF3: 5MHz extends the MIG-OS-MB for subseq. stroke testing.
No burst possible. MS definition 1A 100%, 13D/2 50%
within 1.5 seconds randomly distributed 50ms uo to 110ms).
Requires NW-WF3-5M-FS and MIG-OS-MB-EXT.
WF2-FS-A350
Product No: 105065
WF2-FS-A350 extends MIG-OS-MB or MIG-OS-MB-EXT to
ABD0100.1.2_G lightning test requirement. Max. V/I 1600V/107A
Source impedance V/I= 15 Ohm or 25 Ohm for single stroke testing
Requires MIG-OS-MB-EXT.